Certified liquid-applied systems, a site survey to base the specification on, and technical support through to sign-off, with materials and workmanship guaranteed through Basecare.

  • BBA and ETA certified
  • Tested to C5, ISO 12944
  • Specification support
A building surveyor inspecting a metal roof and making notes on a clipboard

Specification support from survey to sign-off

Every specification starts on the roof, so the system, the preparation and the detailing are written for the condition found rather than taken from a catalogue.

  • Site survey and condition report

    The whole roof surveyed from the roof or by drone, and its condition written up area by area.

  • A written specification

    The system, preparation, detailing and sequence of work, ready to issue for tender.

  • Technical support on site

    Questions answered as the work goes on, with a site visit where the roof needs one.

  • Inspection on completion

    The finished installation checked against the specification before sign-off.

  • Guarantee documentation

    Materials and workmanship covered together through Basecare, confirmed in writing.

  • A maintenance plan

    An inspection cycle that keeps the roof, and the guarantee, in good order.

Certified liquid-applied systems

Four systems, two for treating cut edge corrosion where the sheets are sound and two for coating the whole roof. Each is specified for a particular condition, not sold as a range.

  • STPSilane terminated polymer

    Cut edge corrosion

    A single-component sealant that bonds to plastisol, PVDF and bare galvanised steel alike, cures in damp conditions, and stays flexible as the sheets move with the weather. It is worked into the cut and along the lap as a bead, then coated over, so the cut is sealed against moisture and the corrosion underneath it stops.

    Used for
    Eaves, end laps, verges and the cuts around rooflights and vents
    Applied by
    Brush and knife, from the roof
    Cures
    Moisture curing, in damp conditions
    Finish
    Coated over with the treatment system in the roof colour
    Specify when
    A rust line at the cut, with the sheets still sound
  • PolyurethaneReinforced repair system

    Cut edge corrosion

    Where the coating has pulled back from the cut and the steel is corroding, the cut needs more than a seal. The polyurethane system builds a reinforced band over the cut and a hand's width of sheet either side, encapsulating it so it cannot lift again. Tough enough for foot traffic along the lap and flexible enough to move with the roof.

    Used for
    Advanced stage corrosion, gutter lines and heavily corroded laps
    Applied by
    Brush and roller, with reinforcement where the cut needs it
    Cures
    Single component, cures to a hard flexible film
    Finish
    Colour matched to the roof
    Specify when
    Coating lifting back from the cuts, with staining down the sheets
  • Hybrid polymerSpray roof coating

    Whole roofs

    Once the factory coating on the sheets is failing, the cuts are sealed first and the whole roof is spray coated in one continuous film. The hybrid polymer system covers every lap, fixing and profile without a seam, renews the surface of the roof and gives it one guarantee from ridge to eaves.

    Used for
    Full roof coating over prepared and sealed sheets
    Applied by
    Airless spray
    Cures
    Single component, air curing
    Finish
    Matt or satin, colour matched or changed
    Specify when
    The factory coating is failing across the sheets, not only at the cuts
  • PolyureaFast-cure spray coating

    Whole roofs

    A two-component spray system that cures within minutes of application, so a roof can be coated and back in service the same day, and rain later that afternoon does no harm. The hardest wearing finish in the range, for roofs with heavy foot traffic, plant, or an exposed position.

    Used for
    Full roof coating where speed of cure or wear resistance matters
    Applied by
    Heated plural component spray
    Cures
    Within minutes of application
    Finish
    Colour matched or changed
    Specify when
    The roof has to be back in service quickly, or takes foot traffic and plant

Matching the system to the roof

The survey grades the roof, and the grade sets the specification. Where one roof shows more than one condition, each area is specified for what it needs.

The condition found on survey and what it calls for
Condition found on surveyWhat is specified
A rust line at the cut, sheets soundSTP, sealed and coated
Coating lifting back from the cuts, staining belowPolyurethane reinforced repair, then coated
Factory coating failing across the sheetsCorrosion treated, then a hybrid polymer or polyurea spray coating
Sheets perforated or thinned throughFailed sheets replaced first, then the rest of the roof treated

Certified and independently tested

The systems carry BBA and ETA certification and CE marking, and have been tested to C5 for corrosion resistance under ISO 12944.

Systems certified by

Installed by expert contractors to your specification

The work is carried out by vetted metal roofing contractors who know the systems, working to the written specification and inspected on completion.

Expert contractors hold

Materials and workmanship guaranteed together

One guarantee covers the whole installation, so there is no gap between the product and the people who put it on.

  • Materials and workmanship covered together, through Basecare
  • Every system certified, and installed to the written specification
  • Inspected on completion before the guarantee is issued
  • Kept in place with a maintenance plan

The term depends on the system specified and is confirmed in writing before work starts.

A technician in hi-vis spray coating a grey standing seam roof, the sprayed area lighter behind the gun

Project documents in one place

The survey, the condition report, the specification and the completion records for every project, in one account.

  • Follow the jobSee where things are, from assessment to guarantee.
  • Documents in one placeThe condition report, the quotation and the completion records, ready to download.
  • Message the teamQuestions and updates on the job, in one thread rather than an inbox.

Frequently asked questions

Straight answers on surveys, tenders, substrates and sign-off.

Is every specification based on a survey?

Yes. The roof is surveyed from the roof or by drone and the specification is written for the condition found, covering the system, the preparation, the detailing and the sequence of work.

Can the specification be issued for tender?

Yes. The written specification sets out everything a contractor needs to price the work, and the same document is used to inspect the finished installation.

Which finishes can the systems go over?

Factory coated profiled steel with plastisol or PVDF finishes, and galvanised steel. The survey confirms the substrate and its condition before the system is chosen.

How is the installation checked?

Each installation is carried out by an expert contractor to the written specification and inspected on completion before the guarantee is issued.

What does the guarantee cover?

Materials and workmanship together, through Basecare, provided the system is installed to the specification and maintained on the agreed cycle. The term depends on the system and is confirmed in writing before work starts.

Is technical support available during the works?

Yes. Questions on site are answered as the work goes on, with a site visit where the roof needs one.

Specifying a roof repair?

Send the building details and a surveyor will visit, grade the roof and write the specification.

Survey and specification

The building details first, then a survey and a written specification ready for tender.

Request a specification

The systems

Four certified liquid-applied systems, and where each one is specified.

See the systems